100W broadband 20-6000Mhz 700-2700Mhz 500-2500Mhz GaN RF power amplifier module
All the parameters of PA can be customized depend on your request, if you have any customized parameters pls contact us freely
Technical Specifications
Frequency(MHz) |
20-6000 or Customized |
Input Power(dBm) |
≤10dBm or Customized |
Output Power(dBm) |
50±1(100W ) |
Gain(dB) |
50dB |
Inband Ripple(dB) |
≤±2 or less |
ALC Range(dB) |
≥25 |
Gain flatness |
≤3dB |
Gain Adjustment range(dB) |
0-31dB(1dB step) |
Input/Output VSWR |
≤1.5:1 |
Impedance(ohm) |
50 |
Voltage(V) |
DC+28 |
Working current |
5.5A |
Efficiency |
≥20%-40% or Customized |
Harmonics |
ODD≥15dBc;EVEN≥15dBc |
RF In/Out Connector |
SMA-Female/N-Female |
Monitor interface |
RS-485 or other Customized |
Working Temperature |
-25~+65 degree |
Storage Temperature |
-40 to +85 degree |
Operating Humidity |
0 to 90%, relative |
Weight |
≤1.5KG |
Protection |
High temperature,High VSWR or customized |
Monitoring Function Description:
No. |
Monitoring function |
Description |
1 |
query |
PA ALARM |
When an alarm amplifier failure |
2 |
SWR ALARM |
Amplifier output reflection is too large, VSWR exceeds 3:1, an alarm is generated |
3 |
Over temperature alarm |
Module internal temperature exceeds 75 ºC, generates an alarm and turn off the amplifier until the temperature returns to below 65 ºC, re-open the amplifier |
4 |
Over output power alarm |
When the output power exceeds the nominal full power 2dB is an alarm |
5 |
Input power detection |
Accuracy of ± 1dB |
6 |
Reverse power detection |
Accuracy of ± 1dB |
7 |
output power detection |
Detecting the actual output power amplifier,Accuracy of ± 1dB |
8 |
Temperature detection |
Detection module operating temperature, detection range: -25 ~ +90 ºC, Accuracy of ± 3 ºC |
10 |
SWR |
Detecting amplifier output port VSWR range of 1.2 ~ 4.0 |
11 |
query and set |
PA attenuator Set and query |
Set and query the value of ATT |
12 |
PA switching query and set |
Query and set the state open tube amplifier |
We welcome all OEM orders!