100W 20-512Mhz RF power amplifier module
All the parameters of PA can be customized depend on your request, if you have any customized parameters pls contact us freely
Technical Specifications
Frequency(MHz) |
20-512 or Customized |
Output Power(W) |
50±1(100W ) |
Input Power |
≤0dBm |
ALC Range(dB) |
≥31 |
Gain(dB) |
55 or Customized |
Gain Adjustment range(dB) |
>31/1dB step or Customized |
Gain Adjustment Linearity(dB) |
≤±1 |
Gain Flatness(dB) |
±1(Max) |
Impedance(ohm) |
50 |
Input/output VSWR |
≤1.4:1 |
Noise Figure |
6dB |
Efficiency@CW |
≥20-50% |
Odd harmonics |
≥12dBc |
Even harmonics |
≥15dBc |
Harmonics@CW |
>60dBc |
Voltage(V) |
28V |
Power current |
≤10A |
RF Connector |
SMA-50K or other Customized |
Power supply Interface |
Pull-core capacitance |
Monitor interface |
RS-485 or RS232 or other Customized |
Monitoring communication protocols |
Use Manufacturers protocol or Customized |
Working Temperature |
-40~+65 degree |
Storage Temperature |
-55 to +85 degree |
Operating Humidity |
0 to 90%, relative |
weight |
≤1.5KG |
Surface Color |
Metal color conductive oxide and other color customized |
Remark |
Module with output short circuit or open circuit protection |
Monitoring Function Description:
No. |
Monitoring function |
Description |
1 |
query |
PA ALARM |
When an alarm amplifier failure |
2 |
SWR ALARM |
Amplifier output reflection is too large, VSWR exceeds 3:1, an alarm is generated |
3 |
Over temperature alarm |
Module internal temperature exceeds 85 ºC, generates an alarm and turn off the amplifier until the temperature returns to below 65 ºC, re-open the amplifier |
4 |
Over output power alarm |
When the output power exceeds the nominal full power 2dB is an alarm |
5 |
Input power detection |
Accuracy of ± 1dB |
6 |
Reverse power detection |
Accuracy of ± 1dB |
7 |
output power detection |
Detecting the actual output power amplifier,Accuracy of ± 1dB |
8 |
Temperature detection |
Detection module operating temperature, detection range: -25 ~ +90 ºC, Accuracy of ± 3 ºC |
10 |
VSWR |
Detecting amplifier output port VSWR range of 1.2 ~ 4.0 |
11 |
query and set |
PA attenuator Set and query |
Set and query the value of ATT |
12 |
PA switching query and set |
Query and set the state open tube amplifier |